CSNI2105 CABRI-REPNA-8 TEST. (Abstract last modified 02-MAR-2006)
1.
NAME OR DESIGNATION - CABRI-REPNA-8 TEST 2.
COMPUTER FOR WHICH PROGRAM IS DESIGNED AND OTHER MACHINE VERSION PACKAGES AVAILABLE -
To request or retrieve programs click on the one of the active versions below.
A password and special authorization is required. Explanation of the status codes.
Machines used:
Package-ID Orig.Computer Test Computer
CSNI2105/01
3.
DESCRIPTION OF TEST FACILITY - 4.
DESCRIPTION OF TEST - In the ninth experiment of the CABRI-REPNa programme, dedicated to the study of high burn-up PWR-fuel under RIA conditions, the re-fabricated REPNa8 test rod was submitted to a representative power transient starting from zero-power. 5.
EXPERIMENTAL LIMITATIONS OR SHORTCOMINGS - 6.
PHENOMENA TESTED - 7.
SPECIAL FEATURES OF EXPERIMENT - 8.
COUNTERPART EXPERIMENTS - 9.
STATUS 10.
REFERENCES - 11.
TEST DESIGNATION - REP Na8 12.
PROGRAMMING LANGUAGE -CSNI2105/01: 15.
ESTABLISHMENT - 16.
MATERIAL AVAILABLE -CSNI2105/01: 17.
CATEGORIES - Keywords: FUEL BEHAVIOUR, TRANSIENTS
Program-name Package-ID Status
CABRI-REPNA-8 TEST CSNI2105/01 Arrived
The CABRI REP Na test data provide a very consistent basis for the assessment of fuel behaviour mechanisms relevant for RIA transients. For the CABRI REP Na rods that did not fail, valuable information on fission gas release and especially on cladding deformation have been generated in the test programme. REP Na cladding strain data have been used as a start point for deriving an admittedly simple RIA failure criterion. This is based on a maximum strain which can be tolerated by the cladding, i.e. failure can occur only when this strain level is exceeded.
- For cladding that still retains ductility, failure at high burn-up (50-60 MWd/kg) is predicted beyond a 1% (permanent) diameter strain.
- For cladding that has been embrittled due to e.g. large corrosion, spalling and hydriding, a zero ductility is assumed, i.e. the failure threshold is at onset (0%) of permanent strain.
The conditions under which the ductility decreases from 1% to zero are provisionally set in the paper, taking into account the evidence from the CABRI tests and from ANL laboratory tests. Based on the above, one derives that the lowest failure limit at 60 MWd/kg is ~65-70 cal/g, which applies to heavily corroded/hydrided fuel, i.e. for oxide thickness of ~80 mm and in presence of oxide spalling. For corrosion resistant fuel, i.e. for oxide thickness well below 80 mm and in absence of spalling, the failure threshold at the same burnup is ~100 cal/g.
This failure criterion predicts well three of the four failed REP Na tests, but not the REP Na-1 test. For this, the predicted failure threshold is 63 cal/g, whereas the reported experimental value is 30 cal/g. For CABRI unfailed rods, the predicted failure limit is very close to the enthalpy achieved during the test. When used at its higher degree of conservatism (i.e. ductility = 0), the proposed failure threshold predicts reasonably well also the failed NSRR PWR and BWR rods. In general, more data at prototypical conditions are needed in order to arrive to comprehensive, best-estimate failure predictions. The PIE data of unfailed REP Na rods show a remarkable similarity between the trend exhibited by the cladding strain and by the fission gas release. This is briefly discussed in this paper with regard to a possible FGR mechanism (i.e. it is implied that the gas may mostly be released upon cooling, when cladding constraints are reduced). In any case, it appears that FGR as such has little to do with the mechanism of failure when this occurs at low enthalpy.
For more detailed information visit
http://www.nea.fr/html/dbprog/cabrirepna/CABRI-REPNa.htm and
http://www.nea.fr/html/dbprog/ccvm/csni-rest.html
This test was a complement to the previous REPNa1 and REPNa4 tests. A degraded rod of high burn-up (60 GWd/t) with initial spalling (like REPNa1) was chosen to undergo a large power transient with 60 ms FWHM-width (like REPNa4) with a maximum specific energy deposition of about 95 cal/g at PPN.
The experimental observations indicate that the pin lost its physical integrity 532 ms after the onset of the transient, close to the instant of maximum power. The specific energy deposited in the rod at PPN at this instant amounted to about 67 cal/g. The point of rupture was located approximately 12 cm above PPN (BFC + 42 cm), with a local energy deposition of about 60 cal/g at rupture.
The rupture was accompanied by a gas ejection into the Sodium coolant. No significant fuel-coolant interaction was observed, but traces of fuel were found in the Sodium after the test.
CSNI2105/01: 02-MAR-2006 Masterfiled restricted
A RIA Failure Criterion based on Cladding Strain by C. Vitanza
OECD Halden Reactor Project
Paper presented at the IAEA Technical Committee Meeting on Fuel Behaviour under Transient and LOCA Conditions
CSNI2105/01:
- C. Doderlein, S. Bayle, C. Hee, G. Augier and JJ. Cochaud:
Analysis Report of the REPNa8 CABRI Experiment
Note Technique LERES no.35/98
- C. Doderlein, S. Bayle, C. Hee, G. Augier and JJ. Cochaud:
Quick Look Report of the REPNa8 CABRI Experiment
Note Technique LERES no.35/97
- C. Doderlein:
Addendum to the Quick Look Report of the REPNa8 CABRI Experiment
Note Technique LERES no.01/98
- REPNa-8 Data Sheet
- B. Lacroix:
Examens Non Destructifs du Crayon P07 de l'Assemblage FF0LCMJV
apres Cinq Cycles d'Irradiation dans Gravelines 5
Note Technique SDC/LCND 97-2004 (DR) Indice 0
- J. Larosa and E. Herzog:
Compte-Rendu de Refabrication du Crayon REPNa8 - P07-5
Rapport DMT no.97/243, LECM no.97/048
- E. Ragagli:
Resultats Experimentaux des Examens Non Destructifs relatifs a l'essai REPNa8
Note Technique LERES no.51/97
- M. Lespiaux:
Premiers Resultats obtenus au LECA sur l'Examen Metallographique de la Gaine
du Crayon REPNa8
Note Technique LERES no.47/98, NT SDC/LEC 98/2014 Ind.0
- D. Lespiaux:
REP Na8 Metallographic Examinations performed at the LECA
Note Technique SECI/99-035 Indice 0
- M. Burger, L. Caral, E. Herzog:
CABRI REPNa8 - Examens Visuels apres Essai dans CABRI
Note Technique LERES no.41/98, NT SDC/LEC 98/2010 Ind.0
- M. Burger, R. Marsol, L. Caral and C. Pesce:
CABRI REP Na 8 Examens Visuels Complementaires apres Essai
Note Technique SECI 99.057
Institute de Radioprotection et de Surete Nucleaire
CE Cadarache
13108 St PAUL-LEZ-DURANCE Cedex
Data\ data files + software for plotting curves and extracting to other formats
Experimental reports\ Technical notes on the test results (PDF format)
FABRICE\ Technical notes on the tested rod before test
Post-test examinations\ Technical notes on the post-test examinations
Read Me First.pdf Description of the files
- Y. Integral Experiments Data, Databases, Benchmarks
Home - About Us - Work Areas - Data Bank - Publications - Press Room - List of acronyms - Search