CSNI1014 PATRICIA/GV-6. (Abstract last modified 21-APR-1989)
1.
NAME OR DESIGNATION - PATRICIA/GV-6. 2.
COMPUTER FOR WHICH PROGRAM IS DESIGNED AND OTHER MACHINE VERSION PACKAGES AVAILABLE -
To request or retrieve programs click on the one of the active versions below.
A password and special authorization is required. Explanation of the status codes.
Machines used:
Package-ID Orig.Computer Test Computer
CSNI1014/01 Many Computers
3.
DESCRIPTION OF TEST FACILITY - Steady state steam generator test facility. 4.
DESCRIPTION OF TEST - The test section represents in full scale the secondary side of 9 tubes of a SG type 51, with minimized wall effects and real support plates. The range of parameters tested is for pressure 10 to 70 bars, mass velocity from 20 to 410 kg/m**2/s, and exchanged power up to 100% of nominal. Both steady state and transient tests have been run and both hot and cold legs have been simulated. 6.
PHENOMENA TESTED - Mixture level and entrainment in vertical components, heat transfer SG primary side. 7.
SPECIAL FEATURES OF EXPERIMENT - Provides detailed steam generator data not supplied by integral tests. 9.
STATUS 10.
REFERENCES - 11.
TEST DESIGNATION - GV-6 12.
PROGRAMMING LANGUAGE -CSNI1014/01: 15.
ESTABLISHMENT - 16.
MATERIAL AVAILABLE -CSNI1014/01: 17.
CATEGORIES - Keywords: DATA, HEAT TRANSFER, STEAM GENERATORS
Program-name Package-ID Status
PATRICIA/GV-6 CSNI1014/01 Report
CSNI1014/01: 21-APR-1989 Report Only
F. De Crecy
Etude du Comportement du Secondaire des Generateurs de Vapeur
Note TT/SETRE/173, Octobre, 1985
CSNI1014/01:
- R. Roumy, F. De Crecy, F. Falk, G. Mayet:
Etude du Comportement des Generateurs de Vapeur en Conditions
Accidentelles, Assechement et Renoyage Cote Secondaire
(Note TT/SETRE/155, Mai, 1985)
CEA
Grenoble, France