CSNI0030 TLTA/6432. (Abstract last modified 22-MAY-1992)
1.
NAME OR DESIGNATION - TLTA/6432. 2.
COMPUTER FOR WHICH PROGRAM IS DESIGNED AND OTHER MACHINE VERSION PACKAGES AVAILABLE -
To request or retrieve programs click on the one of the active versions below.
A password and special authorization is required. Explanation of the status codes.
Machines used:
Package-ID Orig.Computer Test Computer
CSNI0030/01 Many Computers
3.
DESCRIPTION OF TEST FACILITY - The Two-Loop-Test-Apparatus (TLTA) is a 1:624 volume scaled BWR/6 simulator. It was the predecessor of the better-scaled FIST facility. The facility is capable of full BWR system pressure and has a simulated core with a full size 8 x 8, full power single bundle of indirect electrically heated rods. All major BWR systems are simulated including lower plenum, guide tube, core region (bundle and bypass), upper plenum, steam separator, steam dome, annular downcomer, recirculation loops and ECC injection systems. The fundamental scaling consideration was to achieve real-time response. A number of the scaling compromises present in TLTA were corrected in the FIST configuration. These compromises include a number of regional volumes and component elevations. 4.
DESCRIPTION OF TEST - 64.45 sqcm small-break LOCA; no high pressure cooling system 5.
EXPERIMENTAL LIMITATIONS OR SHORTCOMINGS - 6.
PHENOMENA TESTED - Channel bypass axial flow and void distribution; core heat transfer; quench front propagation for both fuel rods and channel walls; guide tube and lower plenum flashing; mixture level 7.
SPECIAL FEATURES OF EXPERIMENT - 8.
COUNTERPART EXPERIMENTS - FIST test 6SB2C; ROSA-III test 984. 9.
STATUS 10.
REFERENCES - 11.
TEST DESIGNATION - 6432 12.
PROGRAMMING LANGUAGE(S) USED - 15.
ESTABLISHMENT - 16.
MATERIAL AVAILABLE - 17.
CATEGORIES - Keywords: DATA, LOSS-OF-COOLANT ACCIDENT, TRANSIENTS
Program-name Package-ID Status
TLTA/6432 CSNI0030/01 Arrived
in core.
CSNI0030/01: 22-MAY-1992 Arrived, no report
CSNI0030/01:
CSNI0030/01:
Idaho National Engineering Laboratory
Idaho Falls, Idaho, U.S.A.
CSNI0030/01:
(TOTAL: 19,103,680 bytes)
Current 72,160
Density 1,804,000
Energy 288,640
Mass flow 757,680
Levels 396,880
Mass 288,640
Percent 1,221,360
Differential pressure 2,381,280
Pressure 288,640
Peak clad temperature 116,320
Power 72,160
RHOF 1,334,960
RHOG 1,298,880
RHOL 1,298,880
Pump rpm 108,240
Temperature 4,311,360
Maximum temperature 1,395,840
Saturation temperature 1,451,280
Valve position 216,480