CSNI0020 LOFT/L6-7. (Abstract last modified 25-MAY-1992)
1.
NAME OR DESIGNATION - LOFT/L6-7. 2.
COMPUTER FOR WHICH PROGRAM IS DESIGNED AND OTHER MACHINE VERSION PACKAGES AVAILABLE -
To request or retrieve programs click on the one of the active versions below.
A password and special authorization is required. Explanation of the status codes.
Machines used:
Package-ID Orig.Computer Test Computer
CSNI0020/01 Many Computers
3.
DESCRIPTION OF TEST FACILITY - The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 4.
DESCRIPTION OF TEST - This was the seventh in the NRC L6 Series of Anticipated Transients experiments. Rapid secondary side induced cooldown was studied. The experiment was conducted on 31 September 1981. 5.
EXPERIMENTAL LIMITATIONS OR SHORTCOMINGS - 6.
PHENOMENA TESTED - Phase separation; ECC bypass and penetration; core heat transfer; quench front propagation. 7.
SPECIAL FEATURES OF EXPERIMENT - Only integral research facility with a nuclear core. 8.
COUNTERPART EXPERIMENTS - 9.
STATUS 10.
REFERENCES - 11.
TEST DESIGNATION - L6-7 12.
PROGRAMMING LANGUAGE(S) USED - 15.
ESTABLISHMENT - 16.
MATERIAL AVAILABLE - 17.
CATEGORIES - Keywords: DATA, LOSS-OF-COOLANT ACCIDENT, TRANSIENTS
Program-name Package-ID Status
LOFT/L6-7 CSNI0020/01 Arrived
CSNI0020/01: 25-MAY-1992 Arrived at NEADB
CSNI0020/01:
- B.D. Stitt and J.M. Divine
Experiment Data Report for LOFT Anticipated Transient
Experiment L6-7 and Anticipated Transient with Multiple
Failures Experiment L9-2 (NUREG/CR-2277 - EGG-2121 (September 1981))
- Charles L. Nalezny:
Summary of Nuclear Regulatory Commission's
LOFT Program Experiments
NUREG/CR-3214 - EGG-2248 (July 1983)
- Charles L. Nalezny:
Summary of Nuclear Regulatory Commission's
LOFT Program Research Findings
NUREG/CR-3005 - EGG-2231 (April 1985)
- D.L. Reeder:
LOFT System and Test Description
NUREG/CR-0247 (TREE-1208) July 1978.
- J. Fell and S.M. Modro:
An Account of the OECD LOFT Project
OECD LOFT-T-3907 May 1990.
- Technical Considerations for LOFT Consortium Test Plan,
Prepared for discussion by LOFT Consortium Working Group Meeting
Munich, Germany, July 15-16, 1982 (SEN/LOFT(82)6)
CSNI0020/01:
Idaho National Engineering Laboratory
EG&G Idaho
Idaho Falls, Idaho 83415.
U.S.A.
CSNI0020/01:
Directory TOTAL: 76,113,680
Current 388,800
Control valve 781,920
Computed parameters 7,076,080
Density 1,925,680
Flow velocity 586,320
Frequency 1,916,240
Mass flow 1,368,240
Levels 584,320
Neutron detector 586,000
Differential pressure 3,713,520
Pressure 4,102,960
Power 5,003,040
Rotational speed 195,440
Temperature 47,496,320
Voltage 388,800
- Y. Integral Experiments Data, Databases, Benchmarks
Home - About Us - Work Areas - Data Bank - Publications - Press Room - List of acronyms - Search